Zobrazit stránku 0
RDM
3
WOOD MOISTURE METER
Owner’s Manual
US version - 1.5
For RDM-3 Meters starting with Serial #11925
Delmhorst Instrument Co.
Rev 8
May, 2010
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - Owner’s Manual

RDM3 WOOD MOISTURE METER Owner’s Manual US version - 1.5 For RDM-3 Meters starting with Serial #11925 Delmhorst Instrument Co.

Strany 2

Copyright  2005, Delmhorst Instrument Co. Page 10 of 28 o T° (Temperature Compensation) o JOB (current job) o ALARM (current alarm setting) o MO

Strany 3 - 1. GENERAL DESCRIPTION

Copyright  2005, Delmhorst Instrument Co. Page 11 of 28 UP and DOWN keys can be used to select one of three available options. If COMP TEMP is sele

Strany 4 - 2. Operating Instructions

Copyright  2005, Delmhorst Instrument Co. Page 12 of 28 Select “JOB” and use the LEFT or RIGHT keys to change the job number to the one desired. Whe

Strany 5 - Page 5 of 28

Copyright  2005, Delmhorst Instrument Co. Page 13 of 28 Once a new material/specie is selected, control returns to the Create Job screen. Click SEL

Strany 6

Copyright  2005, Delmhorst Instrument Co. Page 14 of 28 APPENDING DATA TO A JOB: If the chosen job does already exist, the user does not have the op

Strany 7 - 3. Meter Use

Copyright  2005, Delmhorst Instrument Co. Page 15 of 28 job and associated information. The maximum storage capability of the meter is therefore det

Strany 8 - Meter functions:

Copyright  2005, Delmhorst Instrument Co. Page 16 of 28 o View Statistics: This menu option selects the meter’s statistical analysis option. Select

Strany 9 - Page 9 of 28

Copyright  2005, Delmhorst Instrument Co. Page 17 of 28 o The fifth line shows the value of the highest MC reading stored in the specific job. The

Strany 10 - Page 10 of 28

Copyright  2005, Delmhorst Instrument Co. Page 18 of 28 A selected job containing readings offers two other selectable options: “VIEW SET” and “DONE

Strany 11

Copyright  2005, Delmhorst Instrument Co. Page 19 of 28 o Clear Memory: This menu option will erase the storage memory while keeping the default m

Strany 12 - Page 12 of 28

Copyright  2005, Delmhorst Instrument Co. Page 2 of 28

Strany 13

Copyright  2005, Delmhorst Instrument Co. Page 20 of 28 receiving window of the Base Unit. Separation requirements between the meter and Base Unit a

Strany 14 - STORAGE:

Copyright  2005, Delmhorst Instrument Co. Page 21 of 28 Troubleshooting The I/R Link: Most problems tend to occur due to the positioning of the mete

Strany 15 - Page 15 of 28

Copyright  2005, Delmhorst Instrument Co. Page 22 of 28 (temperature mode and electrode type). All can only be accessed in the Setup Menu. Storage M

Strany 16

Copyright  2005, Delmhorst Instrument Co. Page 23 of 28 o Set Power_Off time: This menu option allows the user to change the amount of time allowe

Strany 17 - Page 17 of 28

Copyright  2005, Delmhorst Instrument Co. Page 24 of 28 TAKING A READING The contact pins provided are best for stock up to 6/4. On stock over 6

Strany 18

Copyright  2005, Delmhorst Instrument Co. Page 25 of 28 CARE OF YOUR METER Ø Store your meter in a clean, dry place. The protective carrying cas

Strany 19 - Page 19 of 28

Copyright  2005, Delmhorst Instrument Co. Page 26 of 28 SERVICE FOR YOUR METER Ø Before sending in your meter we recommend you give one of our tra

Strany 20 - Page 20 of 28

Copyright  2005, Delmhorst Instrument Co. Page 27 of 28 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its (Mode

Strany 21

Copyright  2005, Delmhorst Instrument Co. Page 28 of 28 SPECIES LIST: The following 69 species are programmed in the meter. The default species is

Strany 22 - Page 22 of 28

Copyright  2005, Delmhorst Instrument Co. Page 3 of 28 1. GENERAL DESCRIPTION Thank you for your purchase of Delmhorst Instrument Co.’s

Strany 23

Copyright  2005, Delmhorst Instrument Co. Page 4 of 28 2. Operating Instructions -User Guide- This guide provides step-by-step instructions on pow

Strany 24 - TAKING A READING

Copyright  2005, Delmhorst Instrument Co. Page 5 of 28 are important, DO NOT store additional readings. Turn the meter back on and perform a PC down

Strany 25 - Page 25 of 28

Copyright  2005, Delmhorst Instrument Co. Page 6 of 28 Fig. 1 Keypad Layout

Strany 26

Copyright  2005, Delmhorst Instrument Co. Page 7 of 28 POWERING UP THE METER: 1. Press and hold the center (SELECT) button. 2. The meter switches

Strany 27 - Page 27 of 28

Copyright  2005, Delmhorst Instrument Co. Page 8 of 28 o Setup: This menu option selects access to the rest of the meter features: Set Date and Tim

Strany 28

Copyright  2005, Delmhorst Instrument Co. Page 9 of 28 o Default species: Douglas Fir o Default Temperature : 70F o Default Job Number: 1 o